TruSelect™ 2.6 Microcatheter

Why choose TruSelect 2.6

An all-in-one go-to microcatheter to elevate every case

Replace multiple catheters with the workhorse that delivers all-in-one performance. With traditional 2.4 F and 2.8 F options, increasing flow often means losing trackability and prioritizing trackability can limit flow rates and embolic choices. TruSelect 2.6 eliminates these trade-offs, providing all three performance attributes in one microcatheter. The result is simplified access and reliable navigation through tortuous anatomy with reduced catheter exchanges. Built on the trusted TruSelect Microcatheter  platform, the TruSelect 2.6 design extends that familiar performance into broader application across procedures. 


Hand-shapeable tip

TruSelect 2.6 is available in Straight and 80° Bern shapes, both designed to be uniquely hand-shapeable at room temperature without heat or steam. Unlike with polymer-based materials, body temperature will not affect the TruSelect 2.6 tip, giving you confidence that it will retain its shape.

Two gloved hands holding TruSelect.
Purple temperature range icon 23–37°C

Polymer elasticity decreases by 30% within this increase in temperature.

Blue circular icon displaying 37°C temperature

Body temperature

Circular icon displaying 775 degrees Celsius

Tungsten transition temperature

*Data reflects the change in yield stress of a Polyamide-12 when exposed to a temperature transition from 23-37ºC in a wet environment. Refer to the following NIH article for additional information: https://pmc.ncbi.nlm.nih.gov/articles/PMC8549196/ 

Trackability

TruSelect 2.6 maintains the trusted performance and trackability of the TruSelect platform, with a design that removes common trade-offs and supports confident navigation through tortuous anatomy. It tracks smoothly and predictably to your intended destination, delivering the kind of precision traditionally associated with smaller 2.4 F microcatheters.

truselect shown curving in animated vein maintaining form.
Abstract path circular icon

Lowest track force

Track force comparison chart for TruSelect 2.6

Evaluation conducted in a pre-clinical model. Validated TM 92890228 Microcatheter Trackability was used to measure the maximum force required by the microcatheter to track over the guidewire to reach the target treatment site. 150 or 155cm lengths for each microcatheter were selected to represent a worst-case length for both device trackability and device coating durability. 5 units of each microcatheter were tested. All products were tested with straight tips. Bench test study results may not necessarily be indicative of clinical performance. 

Torqueability

Near 1:1 torque response delivers controlled, responsive steering, enhancing how the hand-shapeable tip performs in challenging anatomy.

Truselect multi-segmented shaft design.
Circular path icon with directional arrows

Near 1:1 torque response

Bar chart comparing distal tip rotations

Evaluation conducted in a pre-clinical model. Validated TM 92890267 Torque Response was used to evaluate the torque response at the distal end of the microcatheter when the proximal end is rotated. 150 or 155cm lengths for each microcatheter were selected to represent a worst-case length for device torque response. 5 units of each microcatheter were tested. All products were tested with straight tips. Bench test study results may not necessarily be indicative of clinical performance.

Flow rates

TruSelect 2.6 delivers high-flow performance while providing the lowest track forces amongst leading microcatheters* and an 0.025” ID facilitates compatibility with coils and large embolics.

Medical catheter inserted in blood vessel with coil wrapped in a circle.
Minimalist fast forward arrow line icon

High flow rates

Flow rate comparison chart for TruSelect

*Evaluation conducted in a pre-clinical model. Validated TM 92890262 Flow Rate was used to determine the flow rate at which 100% contrast agent can be delivered through a microcatheter using a pressure injector at the clinical setting of 37ºC and rated pressure (of microcatheter). 150 or 155cm lengths for each microcatheter were selected to represent a worst-case length for device flow rate. 5 units of each microcatheter were tested. All products were tested with straight tips. Bench test study results may not necessarily be indicative of clinical performance. 

person with headset icon.