Boston Scientific accounts are for healthcare professionals only.
Ranger™ Drug-Coated Balloon
Reimbursement
Configure or select a product to continue to order
- Overview
- Clinical Data
- Technical Specifications
- Ordering information
- Training
- Reimbursement
- Resources
Effortless deliverability.
Efficient drug transfer.
Exceptional outcomes.
Now on three platforms – 0.018” OTW, 0.018” Monorail™, and 0.035" OTW.
More choice. Same trusted Ranger.
How it works
The Ranger DCB family utilizes the same TransPax™ coating and the same 2 µg/mm² paclitaxel dose across three platforms. What changes is access and device selection.
- Ranger™ 0.018" OTW — built on the physician-preferred Sterling™ balloon platform with the lowest tip-entry profile of any SFA DCB
- Ranger™ 0.018" Monorail™ — the only DCB on a 200 cm monorail platform, designed for all-access
- Ranger™ 0.035" OTW — built on the Mustang™ catheter platform, designed for high pushability
More platform choice. Same trusted Ranger.
Why choose Ranger
References:
*Gongora et al. Comparative Drug-Coated Balloon Study. JACC Cardiovasc Interv. 2015 doi.org/10.1016/j.jcin.2015.03.020
1. DRG Data, CY 2020, 0.018" PTA Balloons.
2. Boston Scientific Data on File. Ranger Catheter Competitive Testing Report, 92517674. Measurements taken from 6 x 120 devices for Ranger DCB, Lutonix™ 035 DCB, IN.PACT Admiral DCB and Stellarex™ 035 DCB. Lutonix 018 DCB measurements taken from 6 x 150 devices.
3. Boston Scientific Data on File. Ranger Catheter Competitive Testing Report, 92517674. Ranger diameters ≤6mm, testing done with Terumo GLIDESHEATH SLENDER™ 5F.4. COMPARE Clinical Trial 1-Year Results presented by Sabine Steiner, MD. LINC 2020. K-M Primary Patency = 88.4%. RANGER II SFA Pivotal Trial 1-Year Results presented by Marianne Brodmann. LINC 2020. K-M Primary Patency = 89.8%.
4. COMPARE Clinical Trial 1-Year Results presented by Sabine Steiner, MD. LINC 2020. K-M Primary Patency = 88.4%. RANGER II SFA Pivotal Trial 1-Year Results presented by Marianne Brodmann. LINC 2020. K-M Primary Patency = 89.8%.
Featured clinical publications
May 2021
RANGER II SFA RCT
Prospective, Multi-Center, Randomized Controlled Trial Ranger Drug-Coated Balloon vs. Uncoated Balloon (3:1). Follow-up through 5-Years.1
July 2020
COMPARE RCT
COMPARE is the World’s First Head-to-Head Prospective, RCT (1:1) directly comparing SFA DCBs – low dose Ranger DCB vs higher dose IN.PACT DCB.2
References:
1. RANGER II SFA RCT 1-Year Results published in JACC:CI. doi.org/10.1016/j.jcin.2021.03.021
2. COMPARE Clinical Trial 2-Year Results presented by Sabine Steiner, MD. LINC 2021.
3. Based on total drug dose for (4mmx60mm) or (averages for full size matrix) per the Ranger™ Paclitaxel-Coated PTA Balloon Catheter and IN.PACT™ Admiral Instructions for Use.
†Subjects at risk at day 365=255 subjects
‡Subjects at risk at day 1460=184 subjects
Ranger size matrix
| Balloon length (mm) | |||||||
|---|---|---|---|---|---|---|---|
| Diameter | 40 | 60 | 80 | 100 | 120 | 150 | 200 |
| 4 mm | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| 5 mm | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| 6 mm | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| 7 mm | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Minimum sheath | |
|---|---|
| 0.018" OTW / Monorail | OTW 0.035" |
| 5F | 5F |
| 5F | 5F |
| 5F | 6F |
| 6F | 6F/7F |
Over-the-wire catheter with working lengths of 80 cm, 90 cm, 135 cm, and 150 cm
Ordering information
- Ranger OTW 0.014" / 0.018" 80 / 90 cm shaft
- Ranger OTW 0.014" / 0.018" 135 / 150 cm shaft
- Ranger MR 200 cm shaft
Ranger OTW 0.014" / 0.018" 80 / 90 cm shaft
| Product description | Ranger UPN |
|---|---|
| RANGER GLOBAL DCB OTW 4.0 X 40 MM 80 CM | H74939419400480 |
| RANGER GLOBAL DCB OTW 4.0 X 60 MM 80 CM | H74939419400680 |
| RANGER GLOBAL DCB OTW 4.0 X 80 MM 80 CM | H74939419400880 |
| RANGER GLOBAL DCB OTW 4.0 X 100 MM 80 CM | H74939419401080 |
| RANGER GLOBAL DCB OTW 4.0 X 150 MM 90 CM | H74939419401590 |
| RANGER GLOBAL DCB OTW 4.0 X 200 MM 90 CM | H74939419402090 |
| RANGER GLOBAL DCB OTW 5.0 X 40 MM 80 CM | H74939419500480 |
| RANGER GLOBAL DCB OTW 5.0 X 60 MM 80 CM | H74939419500680 |
| RANGER GLOBAL DCB OTW 5.0 X 80 MM 80 CM | H74939419500880 |
| RANGER GLOBAL DCB OTW 5.0 X 100 MM 80 CM | H74939419501080 |
| RANGER GLOBAL DCB OTW 5.0 X 150 MM 90 CM | H74939419501590 |
| RANGER GLOBAL DCB OTW 5.0 X 200 MM 90 CM | H74939419502090 |
| RANGER GLOBAL DCB OTW 6.0 X 40 MM 80 CM | H74939419600480 |
| RANGER GLOBAL DCB OTW 6.0 X 60 MM 80 CM | H74939419600680 |
| RANGER GLOBAL DCB OTW 6.0 X 80 MM 80 CM | H74939419600880 |
| RANGER GLOBAL DCB OTW 6.0 X 100 MM 80 CM | H74939419601080 |
| RANGER GLOBAL DCB OTW 6.0 X 150 MM 90 CM | H74939419601590 |
| RANGER GLOBAL DCB OTW 6.0 X 200 MM 90 CM | H74939419602090 |
| RANGER GLOBAL DCB OTW 7.0 X 40 MM 80 CM | H74939419700480 |
| RANGER GLOBAL DCB OTW 7.0 X 60 MM 80 CM | H74939419700680 |
| RANGER GLOBAL DCB OTW 7.0 X 80 MM 80 CM | H74939419700880 |
| RANGER GLOBAL DCB OTW 7.0 X 100 MM 80 CM | H74939419701080 |
Ranger OTW 0.014" / 0.018" 135 / 150 cm shaft
| Product description | Ranger UPN |
|---|---|
| RANGER GLOBAL DCB OTW 4.0 X 40 MM 135 CM | H74939419400410 |
| RANGER GLOBAL DCB OTW 4.0 X 60 MM 135 CM | H74939419400610 |
| RANGER GLOBAL DCB OTW 4.0 X 80 MM 135 CM | H74939419400810 |
| RANGER GLOBAL DCB OTW 4.0 X 100 MM 135 CM | H74939419401010 |
| RANGER GLOBAL DCB OTW 4.0 X 120 MM 150 CM | H74939419401210 |
| RANGER GLOBAL DCB OTW 4.0 X 150 MM 150 CM | H74939419401510 |
| RANGER GLOBAL DCB OTW 4.0 X 200 MM 150 CM | H74939419402010 |
| RANGER GLOBAL DCB OTW 5.0 X 40 MM 135 CM | H74939419500410 |
| RANGER GLOBAL DCB OTW 5.0 X 60 MM 135 CM | H74939419500610 |
| RANGER GLOBAL DCB OTW 5.0 X 80 MM 135 CM | H74939419500810 |
| RANGER GLOBAL DCB OTW 5.0 X 100 M 135 CM | H74939419501010 |
| RANGER GLOBAL DCB OTW 5.0 X 120 MM 150 CM | H74939419501210 |
| RANGER GLOBAL DCB OTW 5.0 X 150 MM 150 CM | H74939419501510 |
| RANGER GLOBAL DCB OTW 5.0 X 200 MM 150 CM | H74939419502010 |
| RANGER GLOBAL DCB OTW 6.0 X 40 MM 135 CM | H74939419600410 |
| RANGER GLOBAL DCB OTW 6.0 X 60 MM 135 CM | H74939419600610 |
| RANGER GLOBAL DCB OTW 6.0 X 80 MM 135 CM | H74939419600810 |
| RANGER GLOBAL DCB OTW 6.0 X 100MM 135 CM | H74939419601010 |
| RANGER GLOBAL DCB OTW 6.0 X 120 MM 150 CM | H74939419601210 |
| RANGER GLOBAL DCB OTW 6.0 X 150 MM 150 CM | H74939419601510 |
| RANGER GLOBAL DCB OTW 6.0 X 200 MM 150 CM | H74939419602010 |
| RANGER GLOBAL DCB OTW 7.0 X 40 MM 135 CM | H74939419700410 |
| RANGER GLOBAL DCB OTW 7.0 X 60 MM 135 CM | H74939419700610 |
| RANGER GLOBAL DCB OTW 7.0 X 80 MM 135 CM | H74939419700810 |
| RANGER GLOBAL DCB OTW 7.0 X 100 MM 135 CM | H74939419701010 |
| RANGER GLOBAL DCB OTW 7.0 X 120 MM 150 CM | H74939419701210 |
| RANGER GLOBAL DCB OTW 7.0 X 150 MM 150 CM | H74939419701510 |
| RANGER GLOBAL DCB OTW 7.0 X 200 MM 150 CM | H74939419702010 |
Ranger MR 200 cm shaft
| Product description | Ranger UPN |
|---|---|
| RANGER DCB MR 4.0 X 40 MM 200CM | H74939733404020 |
| RANGER DCB MR 4.0 X 60 MM 200CM | H74939733406020 |
| RANGER DCB MR 4.0 X 80 MM 200CM | H74939733408020 |
| RANGER DCB MR 4.0 X 100 MM 200CM | H74939733410020 |
| RANGER DCB MR 4.0 X 120 MM 200CM | H74939733412020 |
| RANGER DCB MR 4.0 X 150 MM 200CM | H74939733415020 |
| RANGER DCB MR 4.0 X 200 MM 200CM | H74939733420020 |
| RANGER DCB MR 5.0 X 40 MM 200CM | H74939733504020 |
| RANGER DCB MR 5.0 X 60 MM 200CM | H74939733506020 |
| RANGER DCB MR 5.0 X 80 MM 200CM | H74939733508020 |
| RANGER DCB MR 5.0 X 100 MM 200CM | H74939733510020 |
| RANGER DCB MR 5.0 X 120 MM 200CM | H74939733512020 |
| RANGER DCB MR 5.0 X 150 MM 200CM | H74939733515020 |
| RANGER DCB MR 5.0 X 200 MM 200CM | H74939733520020 |
| RANGER DCB MR 6.0 X 40 MM 200CM | H74939733604020 |
| RANGER DCB MR 6.0 X 60 MM 200CM | H74939733606020 |
| RANGER DCB MR 6.0 X 80 MM 200CM | H74939733608020 |
| RANGER DCB MR 6.0 X 100 MM 200CM | H74939733610020 |
| RANGER DCB MR 6.0 X 120 MM 200CM | H74939733612020 |
| RANGER DCB MR 6.0 X 150 MM 200CM | H74939733615020 |
| RANGER DCB MR 6.0 X 200 MM 200CM | H74939733620020 |
| RANGER DCB MR 7.0 X 40 MM 200CM | H74939733704020 |
| RANGER DCB MR 7.0 X 60 MM 200CM | H74939733706020 |
| RANGER DCB MR 7.0 X 80 MM 200CM | H74939733708020 |
| RANGER DCB MR 7.0 X 100 MM 200CM | H74939733710020 |
| RANGER DCB MR 7.0 X 120 MM 200CM | H74939733712020 |
| RANGER DCB MR 7.0 X 150 MM 200CM | H74939733715020 |
| RANGER DCB MR 7.0 X 200 MM 200CM | H74939733720020 |
Online medical training and education courses
The EDUCARE online platform makes healthcare education and training more relevant, more comprehensive, more personal, and more accessible. Register to access a library of procedural videos, case studies, training resources, and events.
Reimbursement
The C-code used for Ranger drug-coated balloon is C2623 Catheter, transluminal, drug-coated, nonlaser. C-Codes are used for hospital outpatient device reporting for Medicare and some private payers.
Note: Boston Scientific is not responsible for the correct use of codes on submitted claims; this information does not constitute reimbursement or legal advice.