Indications, safety, and warnings

Slim 7.5 Single-Use Flexible Ureteroscope

Brief Summary Document — HCP

Product

Scivita System (US IFU Version) – IFU SQ0-P-M016-05-09, IFU SQ0-P-M016-53-09


Rx statement

CAUTION: Federal law (USA) restricts this device to sale by or on the order of a physician.  

User qualifications 

The users for this product shall be physicians or the medical staff under the supervision of the physicians. The users are required to undergo sufficient trainings in the endoscopic clinical techniques before they can independently use the device. 

Therefore, this instruction does not include the endoscopic clinical techniques. 

Regarding the endoscopic clinical techniques, please make judgments from the perspectives of professional standpoint. 

Prior to use, please refer to all applicable “Instructions for Use” for more information on Intended Use/Indications for Use, Contraindications, Warnings, Precautions, Potential Adverse Events, and Operator’s Instructions. 

Intended use/Indications for use

Endoscopic Image Processor (model: HDVS-S100) 

This endoscopic image processor is used for endoscopic diagnosis and therapies. It connects to the electronic endoscopes, displaying the images on the monitor detected within the field of view from the body cavity. 

Single-use Flexible Ureteroscope 

This Single-use Flexible Ureteroscope is intended to use in conjunction with endoscopic image processor to provide images through the video monitor for observation, diagnosis, photography and treatment of the urinary system such as urethra, bladder, ureter and renal pelvis. 

Do not use this product for any other purposes. 

Based on a thorough understanding of the endoscope specifications and functions listed here, select the desired endoscope according to the purpose of endoscopy and treatment. 

Contraindications

Endoscopic Image Processor (model: HDVS-S100) 

None. 

Single-use Flexible Ureteroscope 

Absolute Contraindications 

  • Severe systemic hemorrhagic disease 
  • Severe urethral stricture 
  • Acute urinary tract infection 
  • Severe cardiopulmonary disease, unable to tolerate surgery 

Relative Contraindications 

  • Massive hematuria 
  • Severe ureter stricture 

Warnings

Single-use Flexible Ureteroscope 

Do not use excessive force or make sudden bending operations. Do not pull, twist or rotate the angled bend section. Failure to do so may result in injury, bleeding or perforation of patient. It also causes the inability to straighten the bend section during the endoscopy. 

When the endoscopic image is not displayed or the image is frozen, do not operate the bend section, insert or withdraw the insertion section of the endoscope, or use an endoscopic treatment accessory. Failure to do so may result in injury, bleeding and/or perforation of the patient. 

Do not insert or withdraw the endoscope with excessive force or when the endoscope has a poor field of vision, as this may result in injury, bleeding and / or perforation of the patient. 

Do not insert or pull out the insertion section suddenly or forcefully. If it is difficult to insert the endoscope, do not force the insertion; instead, stop the operation immediately. Failure to do so may result in injury, bleeding and/or perforation of the patient. 

If the endoscopic image becomes dark during the operation, it may be because that blood or mucous membranes adhere to the distal end of the endoscope. The endoscope should be carefully withdrawn from the patient’s body to remove blood or mucous membranes, ensuring optimal illumination and safe operation. If user continue to use it in this situation, the temperature of the distal end will rise, causing burns to the patient’s mucous membranes. It may also cause injury to the patient and/or operator. 

When the endoscopic image is not displayed on the monitor, the CMOS may be damaged. The endoscopic image processor should be turned off immediately. If the power is still applied for a long time in this case, the distal end of the endoscope becomes hot, causing burns to the operator or the patient. 

Inspection of the Bending Function 

  • If the movement of the thumb lever is slack or unsmooth, or the bending of the bending section is not smooth, the bending function may be abnormal. In this case, do not use the endoscope as it may not straighten the bending section during the endoscopy, resulting in injury, bleeding and/or perforation of the patient. 

Insert and Withdraw the Endoscope Accessory 

  • Do not forcedly or suddenly insert endoscopic treatment accessories. Otherwise, the endoscopic treatment accessories may suddenly protrude from the distal end of the endoscope, which may result in injury, bleeding, and/or perforation of the patient. 
  • When the endoscope is used in conjunction with an endoscope accessory with energy, the patient’s leakage current will increase, and the device needs to meet the requirement of leakage current, otherwise the patient may be at risk of it. 
  • Select to use the matching laser therapy accessories, otherwise, the image may not be displayed on the monitor when the laser is used. This can result in injury to the patient. 
  • If the tip and aiming beam of the laser probe haven’t seen in the endoscopic image, do not emit laser light, otherwise the patient may be injured and the plier’s tube may be damaged. 
  • Do not withdraw the laser probe when laser is emitted, otherwise the patient may be injured and/or the endoscope may be damaged. 

Cautions

Endoscopic Image Processor (model: HDVS-S100) 

Federal law restricts this device to sale by or on the order of a physician. 

Whenever an improper work in the endoscope is found, stop using it immediately and slowly withdraw it. Using a faulty endoscope can cause harm to the patient. 

When the user operates the bending function, the end of the distal end can be flexibly reacted to the maximum bending by operating with ordinary force. If the force exerted on the thumb lever is too large, it may damage the endoscope or cause injury to the patient. 

Pay attention to the following items when using accessories: 

  • Excessive force or forced passage may cause trauma to the working channel and other serious consequences. 

Adverse events

Endoscopic Image Processor (model: HDVS-S100) 

None. 

Single-use Flexible Ureteroscope 

Possible complications include, but are not limited to: 

  • Bleeding 
  • Fever 
  • Stenosis 
  • Perforation 
  • Laceration 
  • Hematuria 
  • Pain 
  • Hematoma 
  • Urinoma 
  • Infection 
  • Tissue damage