WallFlex™

Colonic Stents

WallFlex™ Colonic Stent
Dedicated flared design is intended to improve obstruction relief and help reduce migration risk
WallFlex™ Colonic Stent
Delivery system allows repositioning of the stent up to about 70% of stent deployment
WallFlex™ Colonic Stent
Nitinol construction aids in improved stent visibility
WallFlex Colonic Soft
WallFlex Colonic Soft

WallFlex™ Colonic Stent

Designed to offer the ultimate combination of delivery system access and stent construction to expand options available for patient treatment and management of colonic strictures caused by malignant neoplasms.

WallFlex™ Colonic Soft Stent

New 9F sized Delivery System for use in a 3.2mm channel scope. Bench tests demonstrate that WallFlex Soft Enteral has lower radial force than current WallFlex Enteral.1

Key Resources

Explore

Product Details

Ordering Information

WallFlex Colonic Stent System*
WallFlex Colonic Stent
Order Number Stent Body Diameter (mm) Flare Diameter (mm) Expanded Stent Length (mm) Working Length (cm) Delivery System Length (cm) Delivery System Diameter (Fr) / Working Channel (mm) Packaging
M00565040 25 30 60 230 270 10 / 3.7 Each
M00565050 25 30 90 230 270 10 / 3.7 Each
M00565060 25 30 120 230 270 10 / 3.7 Each
M00565070 25 30 60 135 175 10 / 3.7 Each
M00565080 25 30 90 135 175 10 / 3.7 Each
M00565090 25 30 120 135 175 10 / 3.7 Each
M00565100 22 27 60 230 270 10 / 3.7 Each
M00565110 22 27 90 230 270 10 / 3.7 Each
M00565120 22 27 120 230 270 10 / 3.7 Each
M00565130 22 27 60 135 175 10 / 3.7 Each
M00565140 22 27 90 135 175 10 / 3.7 Each
M00565150 22 27 120 135 175 10 / 3.7 Each

*Recommended Guidewire .035" WALLSTENT™ Super Stiff Guidewire, Order #18001, (view in catalog).

1 Product with this symbol may be used in Magnetic Resonance environment according to the conditions described in Directions for Use.

WallFlex Colonic Soft Stent System
WallFlex Colonic Stent
Order Number Stent Body Diameter (mm) Flare Diameter (mm) Expanded Stent Length (mm) Working Length (cm) Delivery System Length (cm) Delivery System Diameter (Fr) / Working Channel (mm) Packaging
M00555700 18 23 60 230 270 9 / 3.2 Each
M00555710 18 23 90 230 270 9 / 3.2 Each
M00555720 18 23 120 230 270 9 / 3.2 Each
M00555730 20 25 60 230 270 9 / 3.2 Each
M00555740 20 25 90 230 270 9 / 3.2 Each
M00555750 20 25 120 230 270 9 / 3.2 Each
M00555760 22 27 60 230 270 9 / 3.2 Each
M00555770 22 27 90 230 270 9 / 3.2 Each
M00555780 22 27 120 230 270 9 / 3.2 Each

*Recommended Guidewire .035" WALLSTENT™ Super Stiff Guidewire, Order #18001, (view in catalog).

1 Product with this symbol may be used in Magnetic Resonance environment according to the conditions described in Directions for Use.


Case Studies - WallFlex Enteral Only

Disclaimer: The WallFlex Colonic Stent and WallFlex Soft Colonic Stent are separate products. Performance of the WallFlex Colonic Stent described in the accompanying case studies may not be representative of or indicative of performance by the WallFlex Soft Colonic Stent. As with all case studies, actual results may vary.
Disclaimer: The WallFlex Duodenal Stent and WallFlex Soft Duodenal Stent are separate products.  Performance of the WallFlex Duodenal Stent described in the accompanying case studies is not representative of or indicative of performance by the WallFlex Soft Duodenal Stent.  As with all case studies, actual results may vary.
Disclaimer: The WallFlex Colonic Stent and WallFlex Soft Colonic Stent are separate products. Performance of the WallFlex Colonic Stent described in the accompanying case studies may not be representative of or indicative of performance by the WallFlex Soft Colonic Stent. As with all case studies, actual results may vary.

Read Additional Case Studies - WallFlex Enteral only:
    Therapeutic Endoscopic Management of Synchronous Colon Lesions with WallFlex Colonic ›
Presented by Charles Loewe, MD
Disclaimer: The WallFlex Colonic Stent and WallFlex Soft Colonic Stent are separate products. Performance of the WallFlex Colonic Stent described in the accompanying case studies may not be representative of or indicative of performance by the WallFlex Soft Colonic Stent. As with all case studies, actual results may vary.
Disclaimer: The WallFlex Colonic Stent and WallFlex Soft Colonic Stent are separate products. Performance of the WallFlex Colonic Stent described in the accompanying case studies may not be representative of or indicative of performance by the WallFlex Soft Colonic Stent. As with all case studies, actual results may vary.
    Endoscopic Palliation of Symptomatic Malignant Colonic Obstruction ›
Presented by Sri Komanduri, MD, MS
Disclaimer: The WallFlex Colonic Stent and WallFlex Soft Colonic Stent are separate products. Performance of the WallFlex Colonic Stent described in the accompanying case studies may not be representative of or indicative of performance by the WallFlex Soft Colonic Stent. As with all case studies, actual results may vary.
    Colonic Stent Placement as a Bridge-to-Surgery ›
Presented by Ryan Matsuo, MD
Disclaimer: The WallFlex Colonic Stent and WallFlex Soft Colonic Stent are separate products. Performance of the WallFlex Colonic Stent described in the accompanying case studies may not be representative of or indicative of performance by the WallFlex Soft Colonic Stent. As with all case studies, actual results may vary.

 

Tools & Resources

     Patient Guide
Top