WATCHMAN™

Left Atrial Appendage Closure Device

WATCHMAN Left Atrial Appendage Closure (LAAC) Device
WATCHMAN LAAC Access Sheath
Engineered to conform to the unique anatomy of the LAA to reduce embolization risk1
Unique Intra-­‐LAA design to avoid Left Atrial complications such as erosion and interference with surrounding anatomy1-­‐3
Optimized proximal face design to minimize thrombus formation1-­‐3

The WATCHMAN Left Atrial Appendage Closure Device is a proven alternative to long-term OAC therapy1 for stroke risk reduction in patients with atrial fibrillation.

Key Resources

Explore

Product Details

Left atrial appendage closure (LAAC) with WATCHMAN™ is a proven one-time procedure that reduces the risk of stroke in your non-valvular atrial fibrillation (NVAF) patients and the risk of bleeding that comes with a longterm oral anticoagulant use. The WATCHMAN™ Device is permanently implanted at or slightly distal to the ostium (opening) of the LAA, which is known to be the source of more than 90% of stroke-causing bloods clots in people with non-valvular AF.2 Following the procedure, physicians may prescribe an individual post-implant medication considering patient preference, stroke and bleeding risk. Treatment options may include a dual antiplatelet therapy (DAPT) or an oral anticoagulation therapy with warfarin or NOAC (non-Vitamin-K oral anticoagulation) along with ASS for at least three months.
  • Available in 5 different sizes (21 to 33 mm)
  • Repositionable & Recapturable
  • Device is preloaded in the delivery system
  • 1 size access sheath (14 F Outer Diameter) fits all devices
Proximal Face
Proximal Face
Minimizes surface area facing the left atrium to reduce post-implant thrombus formation. 160 micron membrane (PET) promotes the endothelialization process.
10 Active Fixation Anchors
10 Active Fixation Anchors
Designed to engage tissue for stability
10 Active Fixation Anchors
Intra-LAA Design
Unique intra-LAA design to close the left atrial appendage without compromising surrounding structures such as mitral valve or upper pulmonary vein.
Left Atrial Appendage Closure with the WATCHMAN™ Device

Left Atrial Appendage Closure
with the WATCHMAN™ Device

 

WATCHMAN™ TruSeal™ Access System

The WATCHMAN™ TruSeal™ Access System is utilized to gain access into the LAA and serves as a guiding catheter for the WATCHMAN™ delivery system. TruSeal™ offers increased control without compromise thanks to both excellent torquability and kink resistance at the groin together with a high-quality quick closing valve. The sheath is available in three curves:

New features and benefits compared to the current WATCHMAN™ Access System

WATCHMAN TruSeal Access System
1st global case experience with TruSeal™

1st global case experience
with TruSeal™

 
WATCHMAN TruSeal Access System

WATCHMAN TruSealTM
Access System

The next generation
WATCHMAN Access System
designed for operational efficiency
and optimized procedural performance

 
WATCHMAN™ LAAC: Leading Physicians discuss how to build procedural confidence video

WATCHMAN™ LAAC

Leading Physicians discuss how to build procedural confidence video

Clinical Data

Clinical Data

Patient Selection

Clinical Data

Ordering Information

WATCHMAN™ LAA Closure Device & Delivery System

Order NumberSizeODLengthUnit
M635WS2106021 mm12F/4.0mm75.5 cm1
M635WS2406024 mm12F/4.0mm75.5 cm1
M635WS2706027 mm12F/4.0mm75.5 cm1
M635WS3006030 mm12F/4.0mm75.5 cm1
M635WS3306033 mm12F/4.0mm75.5 cm1

WATCHMAN™ TruSeal™ Access Sheath

Order NumberCurve StyleIDODLengthUnit
M635TS70010Single Curve12F/4.2mm14F/4.8 mm75 cm1
M635TS70020Double Curve12F/4.2mm14F/4.8 mm75 cm1
M635TS70040Anterior Curve12F/4.2mm14F/4.8 mm75 cm1
Find an implanter
Top