FLEXIVE™

Cobalt-Chromium Endovascular Stent System

FLEXIVE™ Cobalt-Chromium Endovascular Stent System

The FLEXIVEᵀᴹ Cobalt-Chromium Endovascular Stent System is the new treatment option for tortuous iliac lesions. This highly visible Cobalt Chromium stent with thin struts is designed to provide outstanding flexibility and conformability.

Explore

Product Details

FLEXIVE™ 

Cobalt-Chromium Endovascular Stent System

The FLEXIVE Cobalt-Chromium Endovascular Stent System is the new treatment option for tortuous iliac lesions. This highly visible Cobalt Chromium stent with thin struts is designed to provide outstanding flexibility and conformability. Best of all, the FLEXIVE design offers rounded corners and edges and an ultra-smooth surface together with the highest compression resistance among Cobalt Chromium balloon-expandable stents on the market.

  

FLEXIBILITY & SMOOTHNESS

The FLEXIVE stent is very flexible and has a very soft and low entry profile tip, designed to provide excellent deliverability even in tortuous anatomies.The FLEXIVE stent has rounded and polished struts, which has been shown to reduce inflammation and the risk of thrombosis.

The unique design of the FLEXIVE stent provides best-in-class compression resistance among Cobalt-Chromium stents, which makes it an excellent choice for difficult-to-cross lesions and tortuous anatomies when deliverability is critical.

EXPRESS™ Vascular LD

Premounted Stent System

The EXPRESS Vascular LD Iliac Pre-mounted Stent System is a stainless steel balloon expandable stent, well known for its superior resistance to compression and great conformability.

    

STRENGTH & CONFORMABILITY

Widely used Iliac stent, well-known for its outstanding compression resistance. Its Tandem Architecture has been designed to provide excellent conformability to vessel anatomies.

The outstanding compression resistance of the EXPRESS Vascular LD Stent makes it an excellent choice for bifurcations or resistant lesions when strength is critical.

Ordering Information

FLEXIVE™

Cobalt-Chromium Endovascular Stent System

UPN STENT BALLOON DATA CATHETER
System
length
Diameter (mm) Length (mm) Balloon Nominal Pressure Balloon Rated
Burst Pressure
Min. Introd.
Sheath
Crossing Profile (mm/in)
WORKHORSE
80 cm 120 cm     (atm) (kPa) (atm) (kPa) (F) (mm)  
H749392
4950028 0
H749392
4950021 0
5 20 7.9 800 14.8 1500 6 2.15 1.80/0.071
H749392
4950038 0
H749392
4950031 0
5 30 7.9 800 14.8 1500 6 2.15
1.80/0.072
H749392
4950048 0
H749392
4950041 0
5 40 7.9 800 14.8 1500 6 2.15 1.80/0.073
H749392
4950058 0
H749392
4950051 0
5 50 7.9 800 14.8 1500 6 2.15 1.80/0.074
H749392
4950068 0
H749392
4950061 0
5 60 7.9 800 14.8 1500 6 2.15 1.80/0.075
H749392
4960028 0
H749392
4960021 0
6 20 7.9 800 13.8 1398 6 2.15 1.86/0.073
H749392
4960038 0
H749392
4960031 0
6 30 7.9 800 13.8 1398 6 2.15 1.86/0.073
H749392
4960048 0
H749392
4960041 0
6 40 7.9 800 13.8 1398 6 2.15 1.86/0.073
H749392
4960058 0
H749392
4960051 0
6 50 7.9 800 13.8 1398 6 2.15 1.86/0.073
H749392
4960068 0
H749392
4960061 0
6 60 7.9 800 13.8 1398 6 2.15 1.86/0.073
H749392
4970028 0
H749392
4970021 0
7 30 7.9 800 12.8 1297 6 2.15 2.03/0.08
H749392
4970038 0
H749392
4970031 0
7 30 7.9 800 12.8 1297 6 2.15 2.03/0.08
H749392
4970048 0
H749392
4970041 0
7 40 7.9 800 12.8 1297 6 2.15 2.03/0.08
H749392
4970058 0
H749392
4970051 0
7 50 7.9 800 12.8 1297 6 2.15 2.03/0.08
H749392
4970068 0
H749392
4970061 0
7 60 7.9 800 12.8 1297 6 2.15 2.03/0.08
H749392
4980028 0
H749392
4980021 0
8 20 7.9 800 12.8 1297 6 2.15 2.03/0.08
H749392
4980038 0
H749392
4980031 0
8 30 7.9 800 12.8 1297 6 2.15 2.03/0.08
H749392
4980048 0
H749392
4980041 0
8 40 7.9 800 12.8 1297 6 2.15 2.03/0.08
H749392
4980058 0
H749392
4980051 0
8 50 7.9 800 12.8 1297 6 2.15 2.03/0.08
H749392
4980068 0
H749392
4980061 0
8 60 7.9 800 12.8 1297 6 2.15 2.03/0.08
H749392
4990038 0
H749392
4990031 0
9 30 7.9 800 12.8 1297 6 2.15 2.14/0.084
H749392
4990048 0
H749392
4990041 0
9 40 7.9 800 12.8 1297 6 2.15 2.14/0.084
H749392
4990058 0
H749392
4990051 0
9 50 7.9 800 12.8 1297 6 2.15 2.14/0.084
LONG
H749392
4990068 0
H749392
4990061 0
9 60 7.9 800 12.8 1297 6 2.15 2.14/0.084
H749392
4950088 0
H749392
4950081 0
5 80 7.9 800 14.8 1500 6 2.15 1.80/0.071
H749392
4960088 0
H749392
4960081 0
6 80 7.9 800 13.8 1398 6 2.15 1.86/0.073
H749392
4970088 0
H749392
4970081 0
7 80 7.9 800 12.8 1297 6 2.15 2.03/0.08
H749392
4980088 0
H749392
4980081 0
8 80 7.9 800 12.8 1297 6 2.15 2.03/0.08

Recommended guidewire: 0.035’’ (0.89 mm). FLEXIVE is equipped with a non-compliant balloon.

EXPRESS™ Vascular LD

UPN STENT BALLOON DATA CATHETER
Short instrument
75 cm catheter
Long instrument
135 cm catheter
Stent Diameter
at NP (mm)
Stent Length(mm) Max. Diameter (mm) Balloon Nominal Pressure Balloon Rated
Burst Pressure
Min. Introd.
Sheath
Crossing Profile  (mm/in)
          (atm) (kPa) (atm) (kPa) (F) (mm)  
H749381
6252075 0
H749381
6252013 0
5 17 9 8 811 12 1216 6 2.16 1.93/0.076
H749381
6253075 0
H749381
6253013 0
5 27 9 8 811 12 1216 6 2.16 1.96/0.077
H749381
62H7540750
49381
6254013 0
5 37 9 8 811 12 1216 6 2.16 1.93/0.076
H749381
6256075 0
H749381
6256013 0
5 57 9 8 811 12 1216 6 2.16 1.96/0.077
H749381
6262075 0
H749381
6262013 0
6 17 9 8 811 12 1216 6 2.16 1.96/0.077
H749381
6263075 0
H749381
6263013 0
6 27 9 8 811 12 1216 6 2.16 2.03/0.080
H749381
6264075 0
H749381
6264013 0
6 37 9 8 811 12 1216 6 2.16 1.93/0.076
H749381
6266075 0
H749381
6266013 0
6 57 9 8 811 12 1216 6 2.16 1.98/0.078
H749381
6272075 0
H749381
6272013 0
7 17 9 8 811 12 1216 6 2.16 1.98/0.078
H749381
6273075 0
H749381
6273013 0
7 27 9 8 811 12 1216 6 2.16 2.06/0.081
H749381
6273075 0
H749381
6273013 0
7 27 9 8 811 12 1216 6 2.16 2.06/0.081
H749381
274075 0
H749381
6274013 0
7 37 9 8 811 12 1216 6 2.16 2.03/0.080
H749381
6276075 0
H749381
6276013 0
7 57 9 8 811 12 1216 6 2.16 2.00/0.079
H749381
6282075 0
H749381
6282013 0
8 17 9 8 811 12 1216 6 2.16 2.06/0.081
H749381
6283075 0
H749381
6283013 0
8 27 9 8 811 12 1216 6 2.16 2.08/0.082
H749381
6284075 0
H749381
6284013 0
8 37 9 8 811 12 1216 6 2.16 2.08/0.082
H749381
6286075 0
H749381
6286013 0
8 57 9 8 811 12 1216 7 2.51 2.18/0.086
H749381
6292075 0
H749381
6292013 0
9 25 11 8 811 12 1216 7 2.51 2.34/0.092
H749381
6294075 0
H749381
6294013 0
9 37 11 8 811 12 1216 7 2.51 2.34/0.092
H749381
6296075 0
H749381
6296013 0
9 57 11 8 811 12 1216 7 2.51 2.34/0.092
H749381
6210207 0
H749381
6212013 0
10 25 11 10 1013 12 1216 7 2.51 2.39/0.094
H749381
6210407 0
H749381
6214013 0
10 37 11 10 1013 12 1216 7 2.51 2.34/0.092
H749381
6210607 0
H749381
6216013 0
10 57 11 10 1013 12 1216 7 2.51 2.31/0.091

Recommended guidewire: 0.035’’ (0.89 mm). Express Vascular LD is equipped with a non-compliant balloon.

Top