VIGILANT™ EL ICD

Powered by EnduraLife™ Battery Technology
Models D232 and D233

VIGILANT™ EL (Extended Longevity ICD) product image
VIGILANT™ EL (Extended Longevity ICD)

The VIGILANTTM EL (Extended Longevity) ICD features EnduraLifeTM Battery Technology in addition to the HeartLogicTM Heart Failure Diagnostic and ImageReadyTM MR-Conditional technology to help manage patient comorbidities.

Key Resources

Explore

Product Details

Heart logic
 
EnduraLife Battery Technology

EnduraLife Battery Technology provides more power to use more of the device, featuring projected longevity up to 17.5 years for VR devices and 16.0 years for DR devices.**

Maximize Device Longevity

 
ImageReady MR-Conditional Systems

Your patients can safely undergo Full Body MRI scans with ImageReady MR-Conditional Systems.†

Discover ImageReady

*Boehmer JP, Hariharan R, Devecchi FG, et al. A Multisensor algorithm predicts heart failure events in patients with implanted devices: resultsfrom the MultiSENSE study. JACC Heart Fail. 2017 Mar;5(3):216-25.

** Assumes: 2.0V RA, 2.0V RV, 0% pacing, 700Ω, No LATITUDE, No Respiratory Rate Sensor, No Heart Failure Sensor Suite.

†When conditions of use are met.

Mechanical Specifications

ModelTypeSize (cm)
(W x H x D)
Mass
(g)
Volume
(cc)
Connector Type
(RA RV LV)
C-Codes
D232VR5.37 x 7.36 x 0.9968.929.5RV: DF4C1722
D233DR5.37 x 7.68 x 0.9971.431.0RA: IS-1; RV: DF4C1721

Longevity Information

Pulse Generator Expectancy Estimation (Implant to Explant) with EnduraLife Battery (All Models)

EnduraLife Battery Technology provides clinically proven, industry-leading projected longevity1-10. The following tables represent sample pulse generator life expectancy estimation (implant to explant) with EnduraLife battery as provided in product labeling. For specific programmable parameter ranges, refer to product labeling at www.bostonscientific.com/manuals, or contact Boston Scientific technical services or your local representative.


Projected Longevitya
Type Pacing Amplitude Pacing 500Ω with
LATITUDE™b
700Ω with LATITUDE™b 900Ω with LATITUDE™b 700Ω no LATITUDE™, RS, or HFSSc
VR
Typical programmed setting VR 2.5 V 15% 15.0 15.1 15.2 17.1
Maximum labeled longevity VR 2.0 V / Off 0% 15.4 15.4 15.4 17.5
DR
Typical programmed setting DR 2.5 V 15% 13.6 13.7 13.8 15.4
Maximum labeled longevity DR 2.0 V 0% 14.2 14.2 14.2 16.0
  • Assumes 70 PPM LRL; DDDR mode; 0.4 ms Pulse Width (RA, RV); sensors On, Heart Failure Sensor Suite On.
  • Projected longevity is calculated assuming 2 maximum energy charging cycles per year, including automatic capacitor re-forms and therapeutic shocks. These calculations also assume 3-channel EGM Onset is on and that the pulse generator spends 3 months in Storage mode during shipping and storage.

a. Assumes ZIP telemetry use for 2 hours at implant and for 40 minutes annually for in-clinic follow-up checks.

b. Assumes standard use of the LATITUDE™ Communicator as follows: Daily Device Check on, quarterly scheduled remote follow ups, and other typical interrogations.

c. Assumes LATITUDE™ Communicator is not used, Respiratory Sensor is Off, and Heart Failure Sensor Suite is Off.

Additional Longevity Information

  • Boston Scientific devices have corporate warranties at 10 years (VR) and 8 years (DR) in available geographies. Warranty information available at www.bostonscientific.com/warranty.
  • Devices use Li/MnO2 chemistry.
  • The Usable Battery Capacity is 1.9 Amp-hours (typical implant to battery capacity depleted).
  • Shelf life is 2 years (before use by).

All trademarks are the property of their respective owner.