CRE™ Balloon Dilators

CRE Fixed and Wireguided Balloon Dilators provide consistent performance for Balloon Endoscopy for optimal control, efficiency and technology. Also available for use in the Dilation Assisted Stone Extraction (DASE) procedure.

Key Resources

Product Brochure The DASE Procedure

Explore

Product Details

Ordering Information

CRE Single-Use Fixed Wire Esophageal Balloon Dilators

CRE Single-Use Fixed Wire Esophageal Balloon Dilators CRE Single-Use Fixed Wire Esophageal Balloon Dilators

Order Number Balloon Inflated O.D. (mm) Balloon Inflated O.D. (Fr) Balloon Length (cm) Inflation Pressures (ATM) Inflation Pressures (kPa) Minimum Working Channel (mm) Catheter Size (Fr) Working Length (cm) Packaging
M00558330 6-7-8 18-21-24 8 3-6-10 304-608-1013 2.8 6 180 Each
M00558340 8-9-10 24-27-30 8 3-5.5-9 304-557-912 2.8 6 180 Each
M00558350 10-11-12 30-33-36 8 3-5-8 304-507-811 2.8 6 180 Each
M00558360 12-13.5-15 36-40.5-45 8 3-4.5-8 304-456-811 2.8 6 180 Each
M00558370 15-16.5-18 45-49.5-54 8 3-4.5-7 304-456-709 2.8 6 180 Each
M00558380 18-19-20 54-57-60 8 3-4.5-6 304-456-608 2.8 6 180 Each
M00558361 12-13.5-15 36-40.5-45 8 3-4.5-8 304-456-811 2.8 6 180 Box 5
M00558371 15-16.5-18 45-49.5-54 8 3-4.5-7 304-456-709 2.8 6 180 Box 5
M00558381 18-19-20 54-57-60 8 3-4.5-6 304-456-608 2.8 6 180 Box 5

  Recommended Inflation Device: Alliance™ II Integrated Inflation System Handle Order #5062, Sterile Syringe Order #5060 (See below)

View Ordering Information for CRE Single-Use Fixed Wire Esophageal Balloon Dilators

CRE Single-Use Wireguided Esophageal / Pyloric / Biliary Balloon Dilators (Indicated for Use in the DASE Procedure)

Order Number Balloon Inflated O.D. (mm) Balloon Inflated O.D. (Fr) Balloon Length (cm) Inflation Pressure (ATM) Inflation Pressure (kPa) Minimum Working Channel (mm) Catheter Size (Fr) Working Length (cm) Packaging
M00558600 6-7-8 18-21-24 5.5 3-6-10 304-608-1013 2.8 / 3.2* / 3.2 (B1) 7.5 180 Each
M00558610 8-9-10 24-27-30 5.5 3-5.5-9 304-557-912 2.8 / 3.2* / 3.2 (B1) 7.5 180 Each
M00558620 10-11-12 30-33-36 5.5 3-5-8 304-507-811 2.8 / 3.2* / 3.2 (B1) 7.5 180 Each
M00558630 12-13.5-15 36-40.5-45 5.5 3-4.5-8 304-456-811 2.8 / 3.2* / 3.2 (B1) 7.5 180 Each
M00558640 15-16.5-18 45-49.5-54 5.5 3-4.5-7 304-456-709 2.8 / 3.2*/ 3.7 / 4.2 (B2) 7.5 180 Each
M00558650** 18-19-20 54-57-60 5.5 3-4.5-6 304-456-608 2.8 / 3.2*/ 3.7 / 4.2 (B2) 7.5 180 Each

Recommended Inflation Device: Alliance™ II Integrated Inflation System Handle Order #5062, Sterile Syringe Order #5060. (See below)

Guidewire included and preloaded in balloon catheter.

*Requires a 2.8mm Olympus™ Brand Endoscope channel or a 3.2mm Pentax™ or Fujinon™ Brand Endoscope channel.

**Esophageal and Biliary application only and does not contain the under balloon RO markers pictured above.

(B1)= Indication requires ≥ 3.2mm Duodenoscope channel

(B2)= Indication requires ≥ 4.2mm Duodenoscope channel

View Ordering Information for CRE Single-Use Wireguided Esophageal / Pyloric / Biliary Balloon Dilators

CRE Single-Use Wireguided Esophageal / Pyloric / Colonic / Biliary Balloon Dilators (Indicated for Use in the DASE Procedure)

Order Number Balloon Inflated O.D. (mm) Balloon Inflated O.D. (Fr) Balloon Length (cm) Inflation Pressure (ATM) Inflation Pressure (kPa) Minimum Working Channel (mm) Catheter Size (Fr) Working Length (cm) Packaging
M00558660 6-7-8 18-21-24 5.5 3-6-10 304-608-1013 2.8 / 3.2* / 3.2 (B1) 7.5 240 Each
M00558670 8-9-10 24-27-30 5.5 3-5.5-9 304-557-912 2.8 / 3.2* / 3.2 (B1) 7.5 240 Each
M00558680 10-11-12 30-33-36 5.5 3-5-8 304-507-811 2.8 / 3.2* / 3.2 (B1) 7.5 240 Each
M00558690 12-13.5-15 36-40.5-45 5.5 3-4.5-8 304-456-811 2.8 / 3.2* / 3.2 (B1) 7.5 240 Each
M00558700 15-16.5-18 45-49.5-54 5.5 3-4.5-7 304-456-709 2.8 / 3.2*/ 3.7 / 4.2 (B2) 7.5 240 Each
M00558710** 18-19-20 54-57-60 5.5 3-4.5-6 304-456-608 2.8 / 3.2*/ 3.7 / 4.2 (B2) 7.5 240 Each

Recommended Inflation Device: Alliance™ II Integrated Inflation System Handle Order #5062, Sterile Syringe Order #5060. (See below)

Guidewire included and preloaded in balloon catheter.

*Requires a 2.8mm Olympus™ Brand Endoscope channel or a 3.2mm Pentax™ or Fujinon™ Brand Endoscope channel.

**Esophageal, Colonic and Biliary application only and does not contain the under balloon RO markers pictured above.

(B1)= Indication requires ≥ 3.2mm Duodenoscope channel

(B2)= Indication requires ≥ 4.2mm Duodenoscope channel

View Ordering Information for CRE Single-Use Wireguided Esophageal / Pyloric/ Colonic / Biliary Balloon Dilators

CRE Single-Use Wireguided Esophageal / Pyloric Balloon Dilators

Order Number Balloon Inflated O.D. (mm) Balloon Inflated O.D. (Fr) Balloon Length (cm) Inflation Pressures (ATM) Inflation Pressures (kPa) Minimum Working Channel (mm) Catheter Size (Fr) Working Length (cm) Packaging
M00558390 6-7-8 18-21-24 5.5 3-6-10 304-608-1013 2.8 7.5 180 Each
M00558400 8-9-10 24-27-30 5.5 3-5.5-9 304-557-912 2.8 7.5 180 Each
M00558410 10-11-12 30-33-36 5.5 3-5-8 304-507-811 2.8 7.5 180 Each
M00558420 12-13.5-15 36-40.5-45 5.5 3-4.5-8 304-456-811 2.8 7.5 180 Each
M00558430 15-16.5-18 45-49.5-54 5.5 3-4.5-7 304-456-709 2.8 / 3.2* 7.5 180 Each
M00558440** 18-19-20 54-57-60 5.5 3-4.5-6 304-456-608 2.8 / 3.2* 7.5 180 Each

Recommended Inflation Device: Alliance™ II Integrated Inflation System Handle Order #5062, Sterile Syringe Order #5060. (See below)

Guidewire included and preloaded in balloon catheter.

*Requires a 2.8mm Olympus™ Brand Endoscope channel or a 3.2mm Pentax™ or Fujinon™ Brand Endoscope channel.

**Esophageal application only.

View Ordering Information for CRE Single-Use Wireguided Esophageal / Pyloric Balloon Dilators

CRE Single-Use Wireguided Esophageal / Pyloric / Colonic Balloon Dilators

Order Number Balloon Inflated O.D. (mm) Balloon Inflated O.D. (Fr) Balloon Length (cm) Inflation Pressures (ATM) Inflation Pressures (kPa) Minimum Working Channel (mm) Catheter Size (Fr) Working Length (cm) Packaging
M00558450 6-7-8 18-21-24 5.5 3-6-10 304-608-1013 2.8/ 3.2* 7.5 240 Each
M00558460 8-9-10 24-27-30 5.5 3-5.5-9 304-557-912 2.8 / 3.2* 7.5 240 Each
M00558470 10-11-12 30-33-36 5.5 3-5-8 304-507-811 2.8 / 3.2* 7.5 240 Each
M00558480 12-13.5-15 36-40.5-45 5.5 3-4.5-8 304-456-811 2.8 / 3.2*  7.5 240 Each
M00558490 15-16.5-18 45-49.5-54 5.5 3-4.5-7 304-456-709 2.8 / 3.2* 7.5 240 Each
M00558500** 18-19-20 54-57-60 5.5 3-4.5-6 304-456-608 2.8 / 3.2* 7.5 240 Each

Recommended Inflation Device: Alliance™ II Integrated Inflation System Handle Order #5062, Sterile Syringe Order #5060. (See below)

Guidewire included and preloaded in balloon catheter.

*Requires a 2.8mm Olympus™ Brand Endoscope channel or a 3.2mm Pentax™ or Fujinon™ Brand Endoscope channel.

**Esophageal or Colonic application only.

View Ordering Information for CRE Single-Use Wireguided Esophageal / Pyloric / Colonic Balloon Dilators

Alliance™ II Inflation System

Order Number Description Packaging
M00550620 Inflation Handle Each
M00550601 Single-Use Syringe / Gauge Assembly Box 5

View Ordering Information for Alliance II Inflation System

Case Studies

Read Additional Case Studies:

Related Procedure