Rotablator™

Rotational Atherectomy System

The standard in rotational atherectomy, The Rotablator System provides an excellent option for treating calcified lesions, with a complete family of products.

Explore

Product Details

Precise

Front-Cutting

  • Realize precise control with a diamond-tipped burr that is designed to immediately engage the lesion to facilitate safe ablation.
  • Selectively ablate calcium preserving the elastic tissue of the vessel wall.

Real-Time Feedback

  • Maintain complete control during ablation through sensitive tactile, auditory, and visual feedback.

Predictable

Stable Rotation

  • Create a smooth lumen at a specific diameter with a burr that spins concentrically around the wire.
  • Control embolic release with a diamond coated burr that ablates plaque into micro particles smaller than a red blood cell.

Size Flexibility

  • Multiple burr size options create predictable lumen size for controlled vessel preparation and uniform stent sizing and expansion (Available in 1.25 to 2.5 mm burr sizes).
  • Achieved desired burr/artery ratio to minimize vessel trauma.

Proven

Long recognized by physicians as the optimal device to ablate calcium in coronary lesions.

Rotablator Console, foot pedal and advancer components Rotablator Console, foot pedal and advancer components

           

Multiple burr size options help to achieve desired burr/artery ratio Multiple burr size options help to achieve desired burr/artery ratio

                                  (Also available in 2.15, 2.25, 2.38, and 2.50 mm)

Effective Tools for Treating Calcified Lesions

Pre-treating calcified lesions with rotational atherectomy can be one of the best ways to enhance proper stent placement

The Rotablator System Features a Full Family of Products

  • RotaWire™ Guide Wires
  • Rotablator RotaLink™ Plus Pre-connected Exchangeable Burr Catheter and Advancing Device
  • Rotablator RotaLink Advancer and Burrs
  • Rotablator Console and Foot Pedal

Guidewires for Directing the Burr

RotaWire Floppy Guide Wire

  • Long, tapered shaft designed for greater flexibility
  • Designed for greater vessel straightening in unfavorable guide wire bias situations

 

RotaWire Extra Support Guide Wire

  • Short, tapered shaft intended to maximize vessel straightening to help create favorable guide wire bias
  • Added support aids in advancing the Rotablator Burr into lesions

 

Burrs and Advancers for Exchangeable Rotational Atherectomy System Advancement

RotaLink Plus System (pre-connected)

  • Burrs can be exchanged for a larger size if needed
  • Reduces inventory space in lab

 

RotaLink System Advancer

  • Separate multiple-sized RotaLink Catheter burrs available
  • Ability to change burr offers procedural flexibility when multiple burrs are anticipated

 

RotaLink System Burrs

  • Burr assortment adds to flexibility
  • Burr sizes from 1.5 mm to 2.5 mm

 

Console and Foot Pedal for Regulating Rotational Burr Speed

Rotablator Console

  • Controls burr rotation speed by regulating air flow to the advancer
  • Monitors and displays burr rotation speed and procedure time

 

Rotablator Dynaglide™ Foot Pedal

  • Activates the burr by initiating the flow of air through the system
  • Facilitates burr exchange or removal by switching the system in and out of Dynaglide mode

600+ Certified Operators in the US 600+ Certified Operators in the US
20+ Years of Proven Clinical Safety and Efficacy 20+ Years of Proven Clinical Safety and Efficacy
900k+ Procedures Performed Worldwide 900k+ Procedures Performed Worldwide

* Based on Boston Scientific sales estimate.

Ordering Information

RotaWire™ Guide Wire

Order Number Model/ Description Length Tip Length Flexibility Spring Tip Diameter Maximum Diameter Quantity
H802 23239-001 2 RotaWire Extra Support Guide Wire with WireClip™  Torquer 330 cm 2.8 cm Stiff 0.009 inch 0.014 inch Box of 5
H802 22824-002 2 RotaWire Floppy Guide Wire with WireClip™  Torquer 330 cm 2.2 cm Flexible 0.009 inch 0.014 inch Box of 5

RotaLink™ System Catheter and Burr

Order Number Model/Description Burr Size Length Maximum Diameter
H802 22782-001A 0 Rotablator RotaLink™  Advancer
(separate from catheter and burr)
     
H802 22768-002 0 RotaLink Exchangeable Burr Catheter 1.25 mm 135 cm 0.58 inch
H802 22768-003 0 RotaLink Exchangeable Burr Catheter 1.50 mm 135 cm 0.58 inch
H802 22768-004 0 RotaLink Exchangeable Burr Catheter 1.75 mm 135 cm 0.58 inch
H802 22768-005 0 RotaLink Exchangeable Burr Catheter 2.00 mm 135 cm 0.58 inch
H802 22768-015 0 RotaLink Exchangeable Burr Catheter 2.15 mm 135 cm 0.58 inch
H802 22768-006 0 RotaLink Exchangeable Burr Catheter 2.25 mm 135 cm 0.58 inch
H802 22768-016 0 RotaLink Exchangeable Burr Catheter 2.38 mm 135 cm 0.58 inch
H802 22768-007 0 RotaLink Exchangeable Burr Catheter 2.50 mm 135 cm 0.58 inch

RotaLink™ Plus Pre-Connected Exchangeable Rotational Atherectomy System

Order Number Model/Description Burr Size Length Maximum Diameter
H749 23631-002 0 RotaLink Pre-connected Exchangeable Burr Catheter and Advancing Device 1.25 mm 135 cm 0.58 inch
H749 23631-003 0 RotaLink Pre-connected Exchangeable Burr Catheter and Advancing Device 1.50 mm 135 cm 0.58 inch
H749 23631-004 0 RotaLink Pre-connected Exchangeable Burr Catheter and Advancing Device 1.75 mm 135 cm 0.58 inch
H749 23631-005 0 RotaLink Pre-connected Exchangeable Burr Catheter and Advancing Device 2.00 mm 135 cm 0.58 inch
H749 23631-015 0 RotaLink Pre-connected Exchangeable Burr Catheter and Advancing Device 2.15 mm 135 cm 0.58 inch
H749 23631-006 0 RotaLink Pre-connected Exchangeable Burr Catheter and Advancing Device 2.25 mm 135 cm 0.58 inch
H749 23631-016 0 RotaLink Pre-connected Exchangeable Burr Catheter and Advancing Device 2.38 mm 135 cm 0.58 inch
H749 23631-007 0 RotaLink Pre-connected Exchangeable Burr Catheter and Advancing Device 2.50 mm 135 cm 0.58 inch

Console

Order Number Model/Description Voltage
H802 22020-039 1 System Console, RC5000 Rota Console, SERV 115 VAC
H802 22020-039L Refurbished Rotablator Console 115 VAC

Accessories

Order Number Model/Description Quantity
H802 21600-003 1 Replacement Braided Air Supply Hose (20 feet) Single
H802 22436-002 1 Dynaglide™  Foot Pedal Single
H802 22151-001 1 Power Cord — North America Single
H802 15901-01 1 Byrne Regulator Single
H802 22196-003 2 WireClip™  Torquer Box of 5

Rotaglide™ Lubricant

Order Number Model/Description Quantity
H749 23548-001 62 Rotaglide Lubricant Mixture 20 cc vials Box of 6

Reimbursement

The C-code used for this product is C1724, catheter, transluminal atherectomy, rotational. C-codes are used for hospital outpatient device reporting for Medicare and some private payers.

Note: Boston Scientific is not responsible for the correct use of codes on submitted claims; this information does not constitute reimbursement or legal advice.

Access GuidePoint for additional reimbursement resources.