Contraindications
Use of ICD systems are contraindicated in: Patients whose ventricular tachyarrhythmias may have reversible cause, such as 1) digitalis intoxication, 2) electrolyte imbalance, 3) hypoxia, or 4) sepsis, or whose ventricular tachyarrhythmias have a transient cause, such as 1) acute myocardial infarction, 2) electrocution, or 3) drowning. Patients who have a unipolar pacemaker.
Warnings
Read the product labeling thoroughly before implanting the pulse generator to avoid damage to the ICD system. Such damage can result in patient injury or death. Program the pulse generator ventricular Tachy Mode to Off during implant, explant or post-mortem procedures to avoid inadvertent high voltage shocks. Always have sterile external and internal defibrillator protection available during implant. If not terminated in a timely fashion, an induced tachyarrhythmia can result in the patient’s death. Ensure that an external defibrillator and medical personnel skilled in cardiopulmonary resuscitation (CPR) are present during post-implant device testing should the patient require external rescue. Patients should seek medical guidance before entering environments that could adversely affect the operation of the active implantable medical device, including areas protected by a warning notice that prevents entry by patients who have a pulse generator. Do not expose a patient to MRI device scanning. Strong magnetic fields may damage the device and cause injury to the patient. Do not subject a patient with an implanted pulse generator to diathermy since diathermy may cause fibrillation, burning of the myocardium, and irreversible damage to the pulse generator because of induced currents. Do not use atrial tracking modes (or an AVT device) in patients with chronic refractory atrial tachyarrhythmias. Tracking of atrial arrhythmias could result in VT or VF. (Applies to dual-chamber devices only.) Do not use this pulse generator with another pulse generator. This combination could cause pulse generator interaction resulting in patient injury or lack of therapy delivery. Do not kink leads. Kinking leads may cause additional stress on the leads, possibly resulting in lead fracture. For specific models, when using a subpectoral implantation, place the pulse generator with the serial number facing away from the ribs. Implanting the pulse generator subpectorally with the serial number facing the ribs may cause repetitive mechanical stress to a specific area of the titanium case, potentially leading to a component failure and device malfunction.
Precautions
For information on precautions, refer to the following sections of the product labeling: clinical considerations; sterilization, storage and handling; implantation and device programming; follow-up testing; explant and disposal; environmental and medical therapy hazards; home and occupational environments. Advise patients to avoid sources of electromagnetic interference (EMI) because EMI may cause the pulse generator to deliver inappropriate therapy or inhibit appropriate therapy.
Potential Adverse Events
Refer to the product labeling for specific indications, contraindications, warnings/ precautions and adverse events. Rx only.
(Rev. M)
The LATITUDE system is designed to tell your doctor within 24 hours if alert conditions are detected by the Communicator. Alert notifications are based on clinician configured alert settings. However, alert notification cannot occur if:
Precautions
The LATITUDE system is designed to notify clinicians within 24 hours if new pulse generator alert conditions are detected by the Communicator. Alert notifications are based on clinician configured alert settings. Pulse generator data will typically be available for review on the LATITUDE system within 15 minutes of a successful interrogation. However, data availability and alert notification can take up to 24 hours or the next business day. Note that data will not be available and alert notification cannot occur if:
Up to two weeks may elapse before LATITUDE first detects the conditions mentioned above and additional time may be required for clinic notification and resolution of the condition. During this time, no new patient data, device data, or alert notifications since the last successful data transmission will be available.
Alert notifications are not intended to be used as the sole basis for making decisions about patient medical care. Alerts can be verified by reviewing supporting diagnostic information stored in the implanted device and viewing information on the LATITUDE clinician website.
Adverse Effects
None known.
Refer to the product labeling for specific instructions for use. Rx only.
(Rev. J)
Product Type
Implantable Cardioverter Defibrillators (ICD)Used in Procedures
ICD (Defibrillator) ImplantationRelated Medical Areas
Cardiac Rhythm ManagementRelated Conditions
Heart Conditions