Managing RV pacing
The ALTRUA 60 series offers an AV Delay extendable to 400ms.
Restoring Chronotropic Competence
The MV Blended Sensor provides a physiologic response to movement and breathing, restoring chronotropic competence(1) and providing Life Adaptive Pacing ™
Collect Valuable Diagnostics
Stored Onset EGMs provides a more complete snapshot of patients’ rhythm before, during, and after an event without sacrificing battery longevity.
ALTRUA 60 EL |
|
|
|
|
|
|
|
Model # |
Type |
Size (HxWxD) |
Mass (g) |
Volume (cc) |
Connector |
Longevity (years) |
Warranty (years) |
S606 |
DR |
49 x 43 x 8 |
29.6 |
12.1 |
IS-1 |
8.83 |
7, 5 full + 2 prorated |
ALTRUA 60 |
|
|
|
|
|
|
|
Model # |
Type |
Size (HxWxD) |
Mass (g) |
Volume (cc) |
Connector |
Longevity (years) |
Warranty (years) |
S603 |
DR |
44 x 42 x 8 |
25.4 |
10.8 |
IS-1 |
6.53 |
5 |
S602 |
DR |
49 x 43 x 8 |
29.6 |
12.6 |
IS-1 compatible/3.2mm |
8.83 |
5 |
S601 |
SR |
42 x 42 x 8 |
23.4 |
10 |
IS-1 |
8.63 |
5 |
ALTRUA 40 |
|
|
|
|
|
|
|
Model # |
Type |
Size (HxWxD) |
Mass (g) |
Volume (cc) |
Connector |
Longevity (years) |
Warranty (years) |
S404 |
DR |
49 x 43 x 8 |
29.6 |
12.1 |
IS-1 |
8.14 |
5 |
S403 |
DR |
44 x 42 x 8 |
25.4 |
10.8 |
IS-1 |
5.94 |
5 |
S401 |
SR |
42 x 42 x 8 |
23.4 |
10 |
IS-1 |
7.74 |
5 |
ALTRUA 20 |
|
|
|
|
|
|
|
Model # |
Type |
Size (HxWxD) |
Mass (g) |
Volume (cc) |
Connector |
Longevity (years) |
Warranty (years) |
S208 |
DR |
49 x 43 x 8 |
29.6 |
12.1 |
IS-1 |
9.75 |
5 |
S205 |
DR |
54 x 49 x 8 |
32.3 |
14.9 |
5/6mm |
9.75 |
5 |
S203 |
DR |
44 x 42 x 8 |
25.4 |
10.8 |
IS-1 |
7.15 |
5 |
S204 |
SR |
44 x 47 x 8 |
24.9 |
11 |
5/6mm |
9.65 |
5 |
S201 |
SR |
42 x 42 x 8 |
23.6 |
10.1 |
IS-1 compatible/3.2mm |
9.65 |
5 |
C2-194
1 Chronotropic competence is defined by the Model of the Cardiac Chronotropic Response to Exercise, Wilkoff et al. A mathematical model of the cardiac chronotropic response to exercise. Journal of Electrophysiology 1989:3: 176-180. Refer to the Physician's System Guide for more information on adaptive-rate therapy. Additional clinical performance was assessed using INSIGNIA Ultra clinical data with the AutoLifestyle feature programmed On. Data on file.* Boston Scientific Corporation. ALTRUA Pacemaker System Guide. 2008. pg 1-20 – 1-25
2 Nowak B, J. Sperzel, F. Rauscha, L. Mont, J. Alzueta, P. J. Senden, and J. Meyer. Diagnostic value of onset-recordings and marker annotations in dual chamber pacemaker stored electrograms. Europace, 2003; 5: 103-109
3 Longevity projections as described in device user manual. Settings: 60ppm, A = 2.5V, V = 1.0V, 500 ohms, 100% paced, MV Blended Sensor ON, Onset EGMs ON, Automatic Capture ON.
4 Longevity projections as described in device user manual. Settings: 60ppm, A = 2.5V, V = 1.0V, 500 ohms, 100% paced, MV Blended Sensor ON, Onset EGMs ON.
5 Longevity projections as described in device user manual. Settings: 60ppm, A = 2.5V, V = 1.0V, 500 ohms, 100% paced, Accelerometer ON, Onset EGMs ON.