TAXUS® Liberté® Long Paclitaxel-Eluting Coronary Stent System

Designed for Drug Delivery in Long Lesions
 Contact Us About This Product
HEALTH CARE PROFESSIONALS
Overview

Advancing Stent Design for Drug Delivery in Long Lesions

Introducing the TAXUS Liberté Long Stent System, the only 38mm length drug-eluting stent (DES) approved for use in the United States.

Engineered for Consistent Drug Distribution

  • Unique, uniform repeating cell geometry supports even drug distribution and delivery
  • Hybrid cell design allows for strength, flexibility and conformability
Drug Comparison

Designed for Improved Deliverability in Long Lesions

  • 27% thinner struts (0.0038")1
  • Low stent crossing profile (0.046")
  • Lowest tip profile (0.017")
  • 10% more trackable stent delivery system1

Improved Stent Apposition and Uniform Neointimal Coverage

  • 25% more uniform neointimal coverage and improved stent apposition2
  • Consistent low levels of neointimal volume

Neointimal Coverage

*Computer modeling of drug distribution uniformity in vascular tissue. Modeling results are for demonstration purposes only and may not necessarily be indicative of clinical performance. Testing completed by Boston Scientific Corporation. Data on file.
1 As compared to the TAXUS® Express²® Stent System. Testing completed by Boston Scientific Corporation. Data on file.
2 As compared to the TAXUS Express Stent System from the TAXUS ATLAS Trial.

Advancing Safety in Long Lesions

The TAXUS Liberté Long Stent is designed for drug delivery while advancing safety and cath lab efficiency.

2-Year Safety Graph

12-month MI Graph /><p>

<img src=

Stent Reduction Rates

*Using the same inclusion criteria (lesions ≥26mm and ≤34mm), a significantly higher percentage of patients in the TAXUS Express Stent control arm required multiple stents to cover the lesion.

In the TAXUS ATLAS Long Lesion Trial, the primary endpoint was met, with a statistically significantly lower 9-month analysis segment Percent Diameter Stenosis for the TAXUS Liberté Long Stent versus the TAXUS Express Stent control (31.65% ± 17.24% versus 32.57% ± 19.28%, p=0.0010).

Product Information

Order Number
Monorail® Catheter
Order Number
Over-the-Wire Catheter
Nominal Expanded
Stent Inner Diameter
Nominal Unexpanded
Stent Length
H7493893638270 H7493893738270 2.75mm 38mm
H7493893638300 H7493893738300 3.00mm 38mm
H7493893638350 H7493893738350 3.50mm 38mm
H7493893638400 H7493893738400 4.00mm 38mm

The C-code used for the TAXUS Liberté Long Stent is C1874: Stent, coated/covered, with delivery system. C-codes are used for hospital outpatient device reporting for Medicare and some private payers.

Note: Boston Scientific is not responsible for the correct use of codes on submitted claims; this information does not constitute reimbursement or legal advice.

All claims based on bench test data. Testing completed by Boston Scientific Corporation. Data on file. Bench test results not necessarily indicative of clinical performance.

Image Gallery
TAXUS® Liberté® Long Paclitaxel-Eluting Coronary Stent System

Product Type

Stent

Used in Procedures

Coronary Angioplasty (PTCA)

Related Medical Areas

Interventional Cardiology

Related Conditions

Heart Conditions

Related Products

Access and Crossing Guide Wires Apex® PTCA Dilatation Catheter Delivery Support Guide Wires Diagnostic Catheters Express²® Coronary Stent System Frontline Guide Wires Guide Catheters Maverick® PTCA Balloon Catheters PROMUS® Everolimus-Eluting Coronary Stent System Quantum™ Maverick® Balloon Catheters TAXUS® Express²® Atom™ Paclitaxel-eluting Coronary Stent System TAXUS® Express²® Coronary Stent System TAXUS® Liberté® Atom™ Paclitaxel-Eluting Coronary Stent System TAXUS® Liberté® Paclitaxel-Eluting Coronary Stent System VeriFLEX™ Bare-Metal Coronary Stent System