AFocus™ Steerable Diagnostic Catheters


AFocus atrial mapping catheters enable the physician to identify potentials inside the atrial structures.

AFocus: 5fr steerable loop is designed to identify potentials inside atrial structures.

AFocus II: 7fr shaft with 4fr deflectable loop for precise positioning. Available with 10 or 20 electrodes in bipolar and unipolar configurations with diameters of 15, 20 and 25mm to cover a wide range of patients.
 Contact Us About This Product

Prescriptive Information

Refer to the operator's manual for complete instructions for use.

Indications
The AFocus steerable electrophysiology catheters are used for electrogram recording and cardiac stimulation during diagnostic electrophysiology studies. The AFocus catheters are to be used to map the atrial regions of the heart.

Contraindications
The AFocus catheter is contraindicated for: Patients with prosthetic valves and patients with left atrial thrombus or myxoma, or interatrial baffle or patch via transseptal approach.

Warnings
This device should be used by or under the supervision of physicians experienced in the techniques of transvenous electrophysiology studies. When using ECG monitoring equipment for electrode placement, the equipment must be either "front end isolated" or have an isolated patient cable. Current leakage from the monitor must not exceed 10 microamps for intracardiac electrodes. Vascular perforation is an inherent risk of any electrode placement. Do not force the catheter through the vessel. The device should not be used in transcatheter ablation. It has not been demonstrated to be safe and effective for radiofrequency ablation. The A-Focus catheter is sterilized with ethylene oxide gas and is intended for one time use only. Do not autoclave. This device should not be used via retrograde approach, and is not recommended for use in the ventricles.

Potential Adverse Effects
To maintain optimal patient safety and electrode catheter integrity, do not wipe this catheter with alcohol. Excessive bending or kinking of the catheter may cause damage to the catheter. Standard grounding procedures should be followed if electrosurgical instruments are used.

Cautions
Federal law (USA) restricts this device to sale by or on order of a physician. Read directions prior to use.

Trademark
A-Focus is a trademark of Irvine Biomedical, Inc.


Image Gallery
AFocus I Catheter AFocus I Catheters AFocus II Catheter

Product Type

Advanced Mapping Catheter

Used in Procedures

Diagnostic Electrophysiology (EP) Study

Related Medical Areas

Cardiac Rhythm Management

Related Conditions

Heart Conditions